Earth bars, neutral links, cable markers and blanking plates for LV electrical panels. Micron Electric UK panel accessories. In stock Sharjah. Delivery across Dubai and UAE.
Blanking Plate for electrical panels in UAE. IEC-compliant, compatible with standard fittings. In stock Sharjah. Call us for same-day delivery to Dubai, Abu Dhabi.
SKU: M BLANP
Cable Marker-EC3 for electrical panels, IEC compliant, ideal for high voltage applications in UAE. Contact via Call us for details.
SKU: MEC-3
Durable Cable Marker for UAE panels, IEC compliant, fits standard electrical setups. Contact via Call us for details.
SKU: MEC-2
EC1 cable marker, DEWA compliant, fits various cables, ideal for UAE panels. Contact via Call us for details.
SKU: MEC-1
Cable Marker-EC0 for UAE panels, IEC compliant, suitable for low voltage. Contact via Call us for compatibility and stock in Sharjah.
SKU: MEC-0
Ideal for UAE electrical systems, IEC compliant, fits diverse panels, contact via Call us for details.
SKU: MEB144W
Ideal for UAE electrical panels, IEC certified, compatible with diverse voltage ratings. Contact us on Call us for details.
SKU: MNL13W
Ideal for UAE electrical panels, IEC certified, fits standard installations. Contact via Call us for details.
SKU: MNL10W
Durable brass neutral link, IEC compliant, fits standard panels. Available in Sharjah. Call us for details.
SKU: MNL7W
Compact 2-pin Earth Connector for UAE panels, IEC compliant. Ideal for tight spaces. Available in Sharjah. Call us for details.
SKU: MEC2P-2PIN
Earth Connector – 1PIN for UAE panels, IEC certified, compatible with major systems. Contact via Call us for details and orders.
SKU: MEC1P-1PIN
A complete, DEWA-compliant LV panel requires more than active components — earth bars, neutral links, cable markers and blanking plates are the finishing hardware that make a panel safe, organized and ready for inspection. Noor Al Bawadi stocks the full range of Micron Electric UK panel accessories for LV distribution boards, MCCs and control panels across UAE.
| Product | Specification | Application |
|---|---|---|
| Earth bar (copper) | M4/M6 studs, 4–24 positions, with fixings | Main and supplementary earthing in LV panels |
| Neutral link (insulated) | 4mm² to 16mm² conductor, 6–24 positions | Neutral distribution terminal bar in distribution boards |
| Cable marker (PVC) | Numbered 0–9, lettered A–Z, clip-on or tie-on | Wire and cable identification in panels |
| Blanking plate (DIN rail) | 1 module / 2 module widths, snap-fit | Covering unused DIN rail spaces in distribution boards |
The main earth bar (protective earth terminal) in an LV panel must be sized to carry the maximum prospective fault current for the duration of the disconnection time. For UAE LV installations: a 16mm² earth bar connection is minimum for final circuit boards; 25–50mm² for sub-distribution boards; 95–150mm² at the main switchboard incomer. DEWA requires all earth terminals to be clearly identified with the earth symbol and green/yellow colour coding. All outgoing protective conductors connect to the earth bar — never to neutral.
Cable markers are essential for identifying individual wires and cores in control panels. Options include: clip-on ferrule markers that slide over wire end-sleeves, adhesive wrap-around markers for larger cables, and tie-on card markers for cable trays. For DEWA panel inspections, all control wiring in panels must be identified at both ends according to the wiring diagram. Micron Electric UK cable markers are available in numbered sets (0–9 repeated), alphanumeric sets and custom printed markers.
Noor Al Bawadi stocks the complete range of Micron Electric UK panel accessories in Sharjah. Earth bars, neutral links, cable markers and blanking plates are available for immediate dispatch. Bulk pricing for panel builders and electrical contractors. Same-day delivery to Dubai, next-day to Abu Dhabi.
Correct earthing is the foundation of electrical safety in UAE LV installations. Earth bars (protective earth terminals) connect all circuit protective conductors to the main earthing system, providing the low-impedance fault path required for overcurrent protection to operate correctly. Combined with lightning protection measures — surge protection devices (SPDs) at the incoming supply and at sensitive equipment — a properly earthed distribution board forms the UAE building's first line of defence against transient overvoltages from lightning strikes and switching surges.
Panel terminals — earth bars, neutral links, and terminal blocks — must be correctly sized for the prospective fault current and installed in compliance with DEWA distribution standards. Noor Al Bawadi supplies Micron Electric UK earth bars and neutral links alongside a full range of panel accessories for UAE panel builders. Our team can advise on terminal sizing for your specific supply rating and fault level. Same-day delivery to Dubai and next-day to Abu Dhabi.
Our experts are here to help you find the perfect electrical components for your needs